-40 ~ +105 (including self-generated heat) . l : agilent e4980a precision lcr meter . rdc : hioki 3540 m ? hitester . idc2 : yokogawa dr130 hybrid recorder + agilent 6692a dc power supply . idc1 : agilent 4284a lcr meter + agilent 42841a bias current source operating temperature range inductance l(uh) tol.(%) lpf6027t-1r0n 1.0 electrical characteristics 3.20 idc1 (max.) test equipments packing style rated dc current(idc) : the value of idc1 or idc2 , whichever is smaller t : taping b : bulk orderingcode rated dc current(a) smd shielded type f (khz) frequency (dimensions in mm) shape & dimensions / recommended solder land pattern rdc 20% dc resistance( ? ) lpf6027 series . idc2(the temperature rise): t= 40 typical at rated dc current test condition . idc1(the saturation current) : l 20% reduction from initial l value . l(frequency , voltage) : f=100 (khz) , v=0.5 (v) idc2 (typ.) 3.90 0.020 3.60 lpf6027t-1r5n 1.5 0.021 150 1.220 0.049 2.20 2.50 lpf6027t-2r2m 2.2 20 LPF6027T-3R3M 3.3 lpf6027t-4r7m 4.7 0.027 3.00 3.20 0.031 2.60 2.80 0.090 1.40 1.80 lpf6027t-150m 15 0.120 1.10 1.40 lpf6027t-100m 10 1.20 lpf6027t-330m 33 0.250 0.80 1.00 lpf6027t-220m 22 0.180 0.90 lpf6027t-470m 47 0.325 0.70 0.35 0.90 lpf6027t-101m 100 0.730 0.48 0.60 0.520 0.60 0.80 lpf6027t-331m 330 2.200 0.27 3.40 30 100 lpf6027t-6r8m 6.8 0.060 1.70 2.10 lpf6027t-680m 68 0.45 lpf6027t-181m 180 1.550 0.34 0.42 lpf6027t-151m 0.40 0.40 lpf6027t-221m 220 1.760 0.30 http://www.abco.co.kr specifications given herein may be changed at any time without prior notice. please confirm technical specifications before you r order and/or use 6.00.2 6.00.2 3.0 max. marking : white 1.3 1.9 2.35 2.2 1.5 3.6 6.6
|